Suzhou 3D Urban GIS DataV
8,657 km² Municipal Spatial Analytics & 3D Urban Data Dashboard
A Three.js and ECharts municipal digital-twin dashboard spanning 8,657 km² of Suzhou and 6,587 3D buildings. As Co-Maintainer (not primary author) of urlien/suzhou-datav, Chain contributed equidistant projection calibration, ASTER GDEM contour smoothing, three spatial GIS algorithms, and standardized statistical panels.
- Three.js r170
- TypeScript 5.6
- ECharts 5.6
- Vite 6
- ASTER GDEM
- Silverman KDE
- Dijkstra Isochrone
- Plate
- CO-01
- Role
- Co-Maintainer
- Status
- Open Source · Co-Maintained
- Year
- 2026
- Scope
- Co-Maintainer (not primary author): Original repository belongs to urlien/suzhou-datav; Chain co-maintains equidistant projection fixes, ASTER GDEM contour processing, spatial GIS algorithms, and standardized stat panel refactors.
Interactive HTML Slide Deck
Navigate with controls, keyboard arrows, slide indicators, or Fullscreen presentation mode.
Calibrates Suzhou 8,657 km² geometry with cos 31.40° = 0.85355 and 10-pass DEM smoothing, explicitly crediting urlien/suzhou-datav.
- cos 31.40° = 0.85355 removes lat/lng aspect distortion
- 10-pass ASTER GDEM hole-filling yields smooth contours
- 6,587 core 3D building models aligned to street grids
- 8,657 km² Full Municipal Coverage
- 6,587 3D Building Models
- 85×85 Cost-Grid Isochrone
- 10+ Standardized Stat Panels
Context & Engineering Constraints
Web 3D municipal dashboards often distort east-west geometry by plotting raw lat/lng degrees, suffer elevation holes in DEM rasters, and distort extreme data spans with unnormalized charts.
System Architecture
- 01
cos 31.40° Equidistant Projection & ASTER GDEM Contours
Applies the Suzhou latitude scale factor (cos 31.40° = 0.85355) and 10-pass ASTER GDEM hole-filling to preserve true geometry across 8,657 km² and 6,587 3D buildings.
- 02
Three Client-Side TypeScript Spatial GIS Algorithms
Computes Silverman adaptive Kernel Density Estimation, Weighted Standard Deviational Ellipses, and 10m–60m Dijkstra isochrones over an 85×85 impedance grid in TypeScript.
- 03
10+ Standardized ECharts Statistical Panels
Refactors innovation progress bars with proper normalization and applies log-scale medical tiering (4702 → 288 → 37 → 17) across 10+ ECharts panels.
Engineering Highlights
- Maintains clear, honest attribution to original repository urlien/suzhou-datav while documenting specific co-maintenance engineering contributions.
- Calibrated cos 31.40° equidistant scaling and 10-pass ASTER GDEM hole-filling so municipal borders, contours, and 6,587 buildings align cleanly.
- Runs Silverman KDE, Weighted SDE, and 85×85 cost-grid Dijkstra isochrones directly in browser TypeScript without a GIS backend.
- Eliminated visual skew across 10+ panels using normalized innovation metrics and logarithmic medical-tier encoding.